{"product_id":"combo-jb-2-century-and-vff30-lockoff-impco-model-j-regulator-vaporizer-lpg-gas","title":"JB-2 CENTURY and VFF30 LOCKOFF Century Model J Regulator Vaporizer LPG Gas","description":"\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eJB2 CENTURY CONVERTER AND VFF30 LOCK OFF \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eFORKLIFT TRUCKS LPG GAS SYSTEM UNIVERSAL SYSTEM PROPANE GAS\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eVACUUM FUELOCK, SHUTS OFF PROPANE WHEN ENGINE STOPS RUNNING\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eINCLUDES INTERNAL FILTER, SILICONE DIAPHRAGM\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e \u003c\/p\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eFEATURES:\u003c\/strong\u003e\u003cspan face=\"Arial\" style=\"font-family: Arial;\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003cul class=\"indent_li\" data-mce-fragment=\"1\"\u003e\n\u003cli class=\"show_bullets\" data-mce-fragment=\"1\"\u003ePropane liquid withdrawal vaporizing regulator\u003c\/li\u003e\n\u003cli class=\"show_bullets\" data-mce-fragment=\"1\"\u003eFor liquid-cooled engines up to 100 HP\u003c\/li\u003e\n\u003cli class=\"show_bullets\" data-mce-fragment=\"1\"\u003edeal for mobile industrial equipment applications\u003c\/li\u003e\n\u003cli class=\"show_bullets\" data-mce-fragment=\"1\"\u003eRated to 312 psi maximum inlet pressure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003ctable class=\"specifications_table\" width=\"100%\" data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003cth colspan=\"2\" data-mce-fragment=\"1\"\u003e\n\u003ch4 id=\"one_liner\" data-mce-fragment=\"1\"\u003eSpecifications\u003c\/h4\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"50%\" data-mce-fragment=\"1\"\u003eFuel Type\u003c\/td\u003e\n\u003ctd width=\"50%\" data-mce-fragment=\"1\"\u003eLPG  Liquid\/Vapor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"50%\" data-mce-fragment=\"1\"\u003eDiaphragm Material\u003c\/td\u003e\n\u003ctd width=\"50%\" data-mce-fragment=\"1\"\u003eSilicone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"50%\" data-mce-fragment=\"1\"\u003eInlet Pressure, Maximum\u003c\/td\u003e\n\u003ctd width=\"50%\" data-mce-fragment=\"1\"\u003e312 psi (21.51 Bar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"50%\" data-mce-fragment=\"1\"\u003eInlet Pressure, Minimum\u003c\/td\u003e\n\u003ctd width=\"50%\" data-mce-fragment=\"1\"\u003e30 psi (207 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"50%\" data-mce-fragment=\"1\"\u003eNominal Outlet Pressure, standard blue spring\u003c\/td\u003e\n\u003ctd width=\"50%\" data-mce-fragment=\"1\"\u003e-1.5\" w.c. (-0.37 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"50%\" data-mce-fragment=\"1\"\u003eHP\/kW\u003c\/td\u003e\n\u003ctd width=\"50%\" data-mce-fragment=\"1\"\u003e100 HP (75 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"50%\" data-mce-fragment=\"1\"\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd width=\"50%\" data-mce-fragment=\"1\"\u003e-40 to +250 degrees F (-40 to +121 degrees C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"50%\" data-mce-fragment=\"1\"\u003eFuel Filtration\u003c\/td\u003e\n\u003ctd width=\"50%\" data-mce-fragment=\"1\"\u003e40 micron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"50%\" data-mce-fragment=\"1\"\u003eHeating Chamber Source\u003c\/td\u003e\n\u003ctd width=\"50%\" data-mce-fragment=\"1\"\u003eRequired for liquid LPG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"50%\" data-mce-fragment=\"1\"\u003eMounting Position\u003c\/td\u003e\n\u003ctd width=\"50%\" data-mce-fragment=\"1\"\u003eVertical recommended. Horizontal position can be used when fuel contamination can be controlled with HD-5 or HD-10 specified LPG fuel\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd width=\"50%\" data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/td\u003e\n\u003ctd width=\"50%\" data-mce-fragment=\"1\"\u003e\n\u003cspan data-mce-fragment=\"1\"\u003eApplications: \u003c\/span\u003eMobile, stationary, industrial, and  automotive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"D Mart Parts","offers":[{"title":"Default Title","offer_id":44640237060179,"sku":"JB-2-CENTURY-VFF30-CENTURY","price":150.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0661\/1691\/1187\/files\/JB-2CENTURYANDVFF30.png?v=1779212032","url":"https:\/\/tires.gabeautotech.com\/products\/combo-jb-2-century-and-vff30-lockoff-impco-model-j-regulator-vaporizer-lpg-gas","provider":"Elite Tire and Gabe","version":"1.0","type":"link"}